Jenis | Pompa Panas Sumber Udara Suhu Sekitar Rendah | Bahan Perumahan | Lembaran plastik, galvanis |
Penyimpanan / Tanpa Tangki | Pemanasan Sirkulasi | Instalasi | Berdiri Bebas, Terpasang di Dinding/Berdiri Bebas |
Menggunakan | Air Panas/Pemanas Lantai/Fancoil Pemanasan Dan Pendinginan | Kapasitas panas | 4,5-20KW |
Pendingin | R410a/ R417a/ R407c/ R22/ R134a | Kompresor | Copeland, Kompresor Gulir Copeland |
Tegangan | 220V 〜inverter,3800VAC/50Hz | Sumber Daya listrik | 50/ 60Hz |
Fungsi | Pemanas Rumah, Pemanas Ruangan & Air Panas, Pemanas Air Kolam Renang, Pendinginan Dan DHW | Polisi | 4.10-4.13 |
Penukar panas | Penukar Panas Shell | Penguap | Sirip Aluminium Hidrofilik Emas |
Bekerja Suhu Sekitar | Minus -25C- 45C | Jenis Kompresor | Kompresor Gulir Copeland |
Warna | Putih, Abu-abu | Aplikasi | Jacuzzi Spa/ Kolam Renang, Hotel, Komersial Dan Industri |
Daya Masukan | 2.8-30KW | Menyorot | pompa panas suhu dingin, pompa panas sumber udara inverter |
Apa prinsip kerja pompa panas sumber udara suhu lingkungan rendah?
Unit pompa panas adalah sistem tertutup yang terdiri dari evaporator, kondensor, kompresor, dan katup ekspansi, yang diisi dengan refrigeran dalam jumlah yang sesuai.
Prinsip dasar operasi pompa panas didasarkan pada prinsip siklus Carnot terbalik: refrigeran cair pertama-tama menyerap panas di udara di evaporator dan menguap membentuk uap (penguapan), dan panas laten penguapan adalah panas yang diperoleh kembali.Kemudian dikompresi menjadi gas bersuhu tinggi dan bertekanan tinggi oleh kompresor dan memasuki kondensor untuk mengembun menjadi cairan (pencairan) untuk mengirim panas yang diserap ke air kolam panas yang diperlukan, Refrigeran cair kembali ke katup ekspansi setelah depressurization dan ekspansi melalui katup ekspansi, menyerap panas dan menguap untuk menyelesaikan siklus.Dengan cara ini, terus menerus menyerap panas dari sumber suhu rendah dan mengeluarkan air kolam renang yang dipanaskan untuk langsung mencapai suhu yang telah ditentukan.
Model | KDR-03 | KDR-05S | KDR-05-G | KDR-07-G | KDR-10-G | KDR-15 | KDR-20 | KDR-25 | |
HP | 3 HP | 5 HP | 5 HP | 7HP | 10HP | 15HP | 20HP | 25HP | |
Sumber Daya listrik | 220V/380V | 220V | 380V | 380V | 380V | 380V | 380V | 380V | |
Daya masukan | 2.8 | 4.2 | 4.7 | 5.2 | 9.2 | 13 | 18.5 | 20.5 | |
Memanaskan output daya pada suhu sekitar yang berbeda. | (20℃) | 10.8 | 16.2 | 18 | 20 | 35.4 | 50 | 71.2 | 78.9 |
(6/7℃) | 9 | 13.7 | 15.3 | 16.9 | 30 | 42.3 | 60 | 66.6 | |
(-6/7℃) | 6.9 | 10.3 | 11.5 | 12.7 | 22.5 | 319 | 453 | 50.2 | |
(-15℃) | 5.9 | 8.8 | 9.9 | 10.9 | 19.3 | 273 | 38.9 | 43 | |
(-20℃) | 5.2 | 7.8 | 8.7 | 9.6 | 17 | 24 | 34.2 | 37.9 | |
Output daya pendinginan | 8.0 | 12.0 | 13.4 | 14.8 | 26.2 | 37.1 | 52.7 | 68.4 | |
Arah outlet kipas | Samping | Samping | Samping | Samping | Samping | Samping | Atas | Atas | |
V\faler koneksi | DN25 | ON25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN50 | |
Tingkat cairan (M3 / H) | 2-3 | 4-5 | 5-6 | 5-7 | 7-10 | 12-15 | 15-20 | 20-25 | |
Dimensi | (MM) | 1152 | 1190 | 1190 | 1190 | 1350 | 1350 | 1800 | 1800 |
(MM) | 422 | 425 | 425 | 425 | 645 | 645 | 1100 | 1100 | |
(MM) | 768 | 1240 | 1240 | 1240 | 1845 | 184S | 2100 | 2100 | |
BERAT (kg) | 130 | 180 | 160 | 220 | 310 | 355 | 630 | 780 |
Dibandingkan dengan pompa panas biasa, pada suhu -10 ℃ dan lebih rendah, suhu penguapan terlalu rendah, menghasilkan lebih sedikit penguapan, menghasilkan volume udara balik kompresor yang lebih sedikit, yang memengaruhi kondensasi dan pelepasan panas.Cabang peningkatan entalpi injeksi yang menghubungkan kompresor ditambahkan ke pompa panas bersuhu sangat rendah.Ketika udara balik kompresor tidak mencukupi, cabang peningkatan entalpi injeksi akan membuat udara untuk kompresor, sehingga pelepasan panas dari kondensor akan meningkat, sehingga masih dapat menghasilkan panas secara normal pada suhu yang sangat rendah.