Jenis | Pompa Panas Sumber Udara Suhu Sekitar Rendah | Bahan Perumahan | Lembaran plastik, galvanis |
Penyimpanan / Tanpa Tangki | Pemanasan Sirkulasi | Instalasi | Berdiri Bebas, Terpasang di Dinding/Berdiri Bebas |
Menggunakan | Air Panas/Pemanas Lantai/Fancoil Pemanasan Dan Pendinginan | Kapasitas panas | 4,5-20KW |
Pendingin | R410a/ R417a/ R407c/ R22/ R134a | Kompresor | Copeland, Kompresor Gulir Copeland |
Tegangan | 220V 〜inverter,3800VAC/50Hz | Sumber Daya listrik | 50/ 60Hz |
Fungsi | Pemanas Rumah, Pemanas Ruangan & Air Panas, Pemanas Air Kolam Renang, Pendinginan Dan DHW | Polisi | 4.10-4.13 |
Penukar panas | Penukar Panas Shell | Penguap | Sirip Aluminium Hidrofilik Emas |
Bekerja Suhu Sekitar | Minus -25C- 45C | Jenis Kompresor | Kompresor Gulir Copeland |
Warna | Putih, Abu-abu | Aplikasi | Jacuzzi Spa/ Kolam Renang, Hotel, Komersial Dan Industri |
Daya Masukan | 2.8-30KW | Menyorot | pompa panas suhu dingin, pompa panas sumber udara inverter |
Kompresor penambah entalpi jet udara dari pompa panas sumber udara suhu sekitar rendah memiliki satu port tambahan udara lebih banyak daripada kompresor air panas pompa panas biasa.Ketika uap yang dihasilkan oleh evaporator ditambahkan dari selubung kompresor ke rongga kompresor, suhu pembuangan kompresor berkurang, panjang zona pertukaran panas penukar panas pompa panas berkurang, area pertukaran panas dua fase meningkat, dan efisiensi pertukaran panas ditingkatkan.
Pada saat yang sama, sistem peningkatan entalpi jet udara tidak hanya menghasilkan suplemen udara, tetapi juga meningkatkan tingkat pendinginan refrigeran sebelum pelambatan, dan meningkatkan panas yang diserap oleh refrigeran di evaporator, sehingga dapat meningkatkan efek pemanasan dan memastikan bahwa sejumlah besar panas bahkan dapat memenuhi kebutuhan lingkungan bersuhu rendah.
Model | KDR-03 | KDR-05S | KDR-05-G | KDR-07-G | KDR-10-G | KDR-15 | KDR-20 | KDR-25 | |
HP | 3 HP | 5 HP | 5 HP | 7HP | 10HP | 15HP | 20HP | 25HP | |
Sumber Daya listrik | 220V/380V | 220V | 380V | 380V | 380V | 380V | 380V | 380V | |
Daya masukan | 2.8 | 4.2 | 4.7 | 5.2 | 9.2 | 13 | 18.5 | 20.5 | |
Memanaskan output daya pada suhu sekitar yang berbeda. | (20℃) | 10.8 | 16.2 | 18 | 20 | 35.4 | 50 | 71.2 | 78.9 |
(6/7℃) | 9 | 13.7 | 15.3 | 16.9 | 30 | 42.3 | 60 | 66.6 | |
(-6/7℃) | 6.9 | 10.3 | 11.5 | 12.7 | 22.5 | 319 | 453 | 50.2 | |
(-15℃) | 5.9 | 8.8 | 9.9 | 10.9 | 19.3 | 273 | 38.9 | 43 | |
(-20℃) | 5.2 | 7.8 | 8.7 | 9.6 | 17 | 24 | 34.2 | 37.9 | |
Output daya pendinginan | 8.0 | 12.0 | 13.4 | 14.8 | 26.2 | 37.1 | 52.7 | 68.4 | |
Arah outlet kipas | Samping | Samping | Samping | Samping | Samping | Samping | Atas | Atas | |
V\faler koneksi | DN25 | ON25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN50 | |
Tingkat cairan (M3 / H) | 2-3 | 4-5 | 5-6 | 5-7 | 7-10 | 12-15 | 15-20 | 20-25 | |
Dimensi | (MM) | 1152 | 1190 | 1190 | 1190 | 1350 | 1350 | 1800 | 1800 |
(MM) | 422 | 425 | 425 | 425 | 645 | 645 | 1100 | 1100 | |
(MM) | 768 | 1240 | 1240 | 1240 | 1845 | 184S | 2100 | 2100 | |
BERAT (kg) | 130 | 180 | 160 | 220 | 310 | 355 | 630 | 780 |
Pompa panas energi udara suhu rendah masih dapat beroperasi secara stabil di bawah kondisi kerja - 25 derajat, yang sangat meningkatkan jangkauan aplikasi pompa panas, sehingga efisiensi termal dari pompa panas biasa sangat berkurang dalam kisaran suhu dari - 10 derajat.Jika beroperasi dalam waktu lama, mesin utama pompa panas energi udara akan memanas.Oleh karena itu, jika Anda ingin menggunakan sistem pemanas pompa panas energi udara bersuhu sangat rendah di lingkungan bersuhu rendah, disarankan untuk menggunakan pompa panas energi udara bersuhu rendah.